Used Grout Plants for Sale

Used Grout Plants for sale. Piling Broker offers a wide range of used Grout Plants for sale, including some of the leading brands such as used CHEMGROUT, COLCRETE, Metax, PENNDRILL, Belgrade, CASAGRANDE, DMI, Hany, High Shear and Intric Grouting Solutions and more.

14 Products

Sort by

Portable, 200 BBL, LoProfile Cement Silo image
USED
$88,000 USD
Belgrade 2024 Portable,200 BBL, LoProfile Cement Silo available for sale, surplus to their present needs.
Legal 8’6 wide x legal 13’-6 tall, 26’-0 overall length, 8” x 17’ discharge screw, 8” x 5’ auger

extension, 5 HP three phase motor and gear box drive, manual slide gate assembly, solimar vibratory discs, manifold assembly with airline

and fittings, filter/regulator and (3) manual controls, (1) 10,000# axle with electric brakes and lights, manhole with pop off valve, (4)
leveling jacks, 330 sq. ft. pulse jet dust collector, pop off valve, 10 ¾” x 4’ vinyl boot sock with clamp,

United States

Belgrade
Grout Plants
0 HR
2024
KCP concrete pump KTP1160-8 image
USED
$80,000 USD
KCP concrete pump, never used 2026, 0 hours

Model KTP1160-8 
Maximum Output 78m³/h (102yd³/h) 
38 strokes per minute
Concrete Pressure 70bar (1,015psi)

United States

KCP
Grout Plants
0 HR
2026
Used 30T silo image
USED
Contact seller for pricing
Used 30T silo by Penndrill

United States

PENNDRILL
Grout Plants
500 HR
2016
Pile Testing Equipment  image
USED
Contact seller for pricing
we have 3 nice pile testing setups

United States

Piletest
Grout Plants
10 HR
2015
Used PennDrill silo image
USED
$40,000 USD
Like new PennDrill silo for sale on Piling Broker, model PD15

United States

Penndrill
Grout Plants
10 HR
2024
Colcrete Colmixer 4/10 grout pump image
USED
Contact seller for pricing
Description: Colcrete Colmixer 4/10 grout pump.
Fully refurbished in like new condition
Colcrete 4/10 Skidmounted Diesel/Mechanical drive goutmixer/Pump. Progressive Cavity Pump. 1 ea 120 liter (32 gal) and 1 ea 190 liter (51 gal) agitator. Up to 3.5 m3/hr (925 gal/hr) or 16 gal/min output and max 10 bar (145 psi) of output pressure. Very reliable and rugged style pump.

United States

COLCRETE
Grout Plants
Used Scheltzke MPS 110-D-C-AUT Grout Plant image
USED
$96,000 USD
Description: 
Scheltzke MPS 110-D-C-AUT Grout Plant
Hours: 1191
Unit is in a great working condition and ready to be used on your next project.
22 Ton Silo w/STS FS16-4000-HY Screw Conveyor for additional cost of 
$21,000.00

United States

Scheltzke
Grout Plants
1191 HR
Used Olin 5 140CA pump on trucks image
USED
$137,000 USD
Description: Used Olin 5 140CA pump on tracks
We have two of those pumps in like new condition. 
Year: 2020
Model 5 140CA
JCB EcoMax 4.8
https://olinpump.com/pumps/5-
140ca/

United States

OLIN
Grout Plants
1471 HR
2020
ChemGrout CG-500/031 Grout Pump image
USED
$14,000 USD
Chem Grout CG-500/031 High Capacity  Geotech Series for sale.  Overall runs great. 
Model: CG500/031/GH/GT
 Description: 
Skid Mounted Self-Contained Gasl/Hydraulic Grout Plant 
20 HP Gas Engine with Electric Start
 Features: - Water Reservoir - 2 Mixing Tanks Extras Included: - (6) 25ft hoses - (1) Diaphragm type throttling valve

United States

CHEMGROUT
Grout Plants
2010
Used Tecniwell Diesel Grout Plant TWMG57/D image
USED
Contact seller for pricing
Description:
Year: 2016
Current Hours: 294.3
Weight: 5070 Pounds
Engine: HATZ Diesel 3L43C
Horse powers: 32HP

United States

Tecniwell
Grout Plants
294 HR
2016
High Shear Grout Plant System 7/14B Hatz diesel image
USED
$8,000 USD
High Shear Grout Plant System 7/14B with a Hatz diesel motor. Self-contained plant capable of colloidally mixing and pumping a wide range of grouts including sand grouts with sand/cement ratios of up to 3:1 and cement grouts with water/cement ratios down to 0.36.
See description picture for more information.

United States

High Shear
Grout Plants
2570 HR
Intric Grouting Solutions, RM1200, Grout Pump image
USED
$22,000 USD
**PRICE REDUCED**
**NEW**
**3 UNITS AVAILABLE**
**$22,000/EA**
**FREE SHIPPING TO CONTINENTAL USA*
New progressive cavity grout pump with mixing capabilities, gasoline motor powers hydraulic system. Machine has agitator/mixer in holding hopper, 1.5 CY hopper, mounted on a forklift skid base for easy transport around a job site. Variable speed and forward/reverse function. Great for mixes delivered with ready-mix truck, or a mixing paddle can be purchased from Intric Grouting Solutions to convert to mixer/pump.

United States

Intric Grouting Solutions
Grout Plants
2024
Used Metax JMP5 Pump image
USED
$48,000 USD
Description: Used Metax JMP5 Pump

United States

METAX
Grout Plants
Used Colcrete grout plant 7/14. image
USED
$12,000 USD
Used Colcrete grout plant 7/14.
Diesel Unit

United States

COLCRETE
Grout Plants
2004

Grout plants mix and pump cementitious grout for micropiles, ground anchors, soil nailing, jet grouting and ground improvement. A plant usually combines a high-shear or colloidal mixer, a holding agitator and a pump, with silos and batching added on larger set-ups.

Match the plant to the method. Jet grouting demands high pressure and steady output, while anchor and micropile grouting is generally lower pressure. Mixing capacity, pump pressure and flow rate are the figures to compare.

Frequently asked questions

What is a colloidal mixer and why does it matter?

A high-shear mixer that breaks up cement particles and wets them thoroughly, producing a more stable grout that bleeds and separates less than one from a simple paddle mixer. For anchors and micropiles that stability affects grout quality directly.

What size grout plant do I need?

Work back from your grout consumption per shift and the pressure your method requires. Jet grouting needs markedly higher pressure and output than anchor or micropile work, so a plant suited to one may be unsuitable for the other.

What should I check on a used grout plant?

Cement slurry is abrasive, so check the mixer paddles or rotor for wear and the pump seals and valves for leaks — these are the parts that fail first. Ask about the cleaning routine it was kept on, since grout left to set in the lines is a common cause of blockages.